All tests Full fold vanes long and short in centre bolt 850rpm 100kg/ha 14km/h Test01 Brushes fitted to rear curtain and outside curtains Very effective Leaks inwards creating centre shower of granules Vanes sweep through the centre shower smashing the granules Test02 Brushes removed, cardboard curtain 5mm above top of vane Leaks badly at rear of drop zone Test03 Brushes fitted, small inner curtains fitted to lower edges of chute divider Still leaks inwards creating centre shower 3 rows of 3 trays tested: 3trays at centre line, 3trays at 5m, 3trays at 7m Results: 7m = 5.3 5m = 5.7 CL = 13.5 Need to stop centre leaks and adjust chute to stop centre overlap